IK01-IK06 Pendulum Impact Device
IK01 to IK06 pendulum impact device is designed according to GB2099.1-2008, IEC60884-1 figure 22-26, GB2423 and IEC60068-2-75. It is applied to sheet metal for mechanical impact testing. The mounting bracket can be moved left to right, and impact angle can be adjusted. This device is for 2J below low energy impact testing.
Specification
● Swing pipe: 1000mm (L)*9mm (outer diameter)*0.5mm (thickness), 100±1g (mass)
● Mounting bracket: 10±1kg, X and Y axis can be adjusted, rotate at ±90 degrees
● Characteristics 0f Striking Elements
Energy/J |
≤1 ±10% |
2±5% |
5±5% |
10±5% |
20±5% |
50±5% |
Equivalent mass±2%kg |
0.25(0.2) |
0.5 |
1.7 |
5 |
5 |
10 |
Material |
Nylon |
steel |
||||
R/mm |
10 |
25 |
25 |
50 |
50 |
50 |
D/mm |
18.5(20) |
35 |
60 |
80 |
100 |
125 |
f/mm |
6.2(10) |
7 |
10 |
20 |
20 |
25 |
r/mm |
– |
– |
6 |
– |
10 |
17 |
l/mm |
Depends |
● Fall height
Energy/J |
≤1 ±10% |
2±5% |
5±5% |
10±5% |
20±5% |
50±5% |
Equivalent mass±2%kg |
0.25(0.2) |
0.5 |
1.7 |
5 |
5 |
10 |
Material |
Nylon |
steel |
||||
R/mm |
10 |
25 |
25 |
50 |
50 |
50 |
D/mm |
18.5(20) |
35 |
60 |
80 |
100 |
125 |
f/mm |
6.2(10) |
7 |
10 |
20 |
20 |
25 |
r/mm |
– |
– |
6 |
– |
10 |
17 |
l/mm |
Depends |
● Degrees of protection against external mechanical impacts
IK01 |
IK02 |
IK03 |
IK04 |
IK05 |
IK06 |
IK07 |
IK08 |
IK09 |
IK10 |
0.14J |
0.2J |
0.35J |
0.5J |
0.7J |
1J |
2J |
5J |
10J |
20J |